Pellet Stove Installation
Complete pellet stove setup — hearth, venting, air kit, electrical, all in one.
Learn moreMost pellet stove troubles — a stalled auger, a burnt igniter, a sluggish exhaust blower, a control-board fault — trace back to ash buildup, so we diagnose and repair the failed part and clean the stove as part of the same visit. Bundling the cleaning into the repair is the difference between a fix that holds and one that fails again next month. One crew, one trip, a stove that's both repaired and tuned to keep running.
A pellet stove is the most electromechanical appliance in the house, and that's exactly why it breaks in ways a wood stove never does. Five systems have to hand off in sequence every time it lights — the auger meters pellets, the igniter heats the burn pot, the combustion blower establishes exhaust flow, a vacuum or pressure switch confirms that flow, and the control board orchestrates the whole startup before the convection fan ever moves heat into the room. When any one link fails, the board refuses to proceed and the stove either won't light or locks out mid-burn. Texas Service Experts diagnoses these faults to the component, focused on getting the right part right the first time instead of throwing boards at a no-heat call — and because it's the same whole-home crew, the vent and venting the stove depends on get a look too, not just the part that failed.
The control board, not the parts bin, is where diagnosis starts. We read the stored error or status code and trace it: a no-ignition code points to the igniter element, the auger feed, or the hopper; a flame-loss or shutdown code points to the combustion blower, the vacuum/pressure switch, or a fouled exhaust path; an over-temp or fan code points to the convection blower or its sensor. Pellet igniters are wear items that fail every few seasons, auger motors seize or shear, and blowers grind their bearings out — but the symptom rarely names the culprit, so we test each link rather than guess. How this differs from pellet-stove-installation: install builds the vent, runs the circuit, and commissions a brand-new stove, while repair never touches the vent route — it isolates and replaces the failed part inside a unit that already passed commissioning.
Behind a large share of repairs is fly-ash, the silent driver — which is why we treat deep-cleaning as part of the fix rather than an upsell. Pellet exhaust packs fine ash into the burn pot holes, the heat-exchanger passages, the exhaust path, and the area around the combustion blower and the vacuum-switch port. That buildup starves the burn of air, which overworks the igniter and blower and trips the safety switch into a lockout — so a 'failed' switch or a 'weak' blower is often a clean stove away from working. We clear the ash the diagnosis points to, so the replacement part isn't fighting the same restriction that killed its predecessor.
A test-burn and an honest repair-versus-replace call close out every repair. We run the stove through a full light-off, hold it through steady-state, and confirm the combustion and convection blowers, the auger feed, and the safety switches all behave across the cycle, with an ambient CO check before we leave. We quote parts and labor as line items so the math is yours: a single igniter or blower on a healthy stove is an easy yes, but when a fifteen-year-old unit starts stacking board, auger, and blower failures in one season, we'll tell you plainly that a new stove is the better spend.
Pull the error/status code and reproduce the fault.
We test the igniter, auger, blowers, switches, and board until the failed part shows itself.
We swap the bad component and clear out the fly-ash that either caused it or hid it.
Full test-burn, safety-switch check, and CO check.
We've worked on 1,000+ DFW homes over 10+ years. Every job — small sweep or full rebuild — runs the same way: certified technicians, written quotes, photo reports, warranty in writing.
Code-read diagnosis to the failed component, not guesswork
OEM-grade augers, igniters, blowers, switches, and boards
Fly-ash deep-clean built into the repair
Honest line-item repair-vs-replace advice
Family-owned, CSIA-certified, NFPA 211–compliant. We're the team you call when you want it done right the first time — no rotating subcontractors, no upsell pressure, no surprises. Same techs, same trucks, same standard.

The NFPA recommends a Level 1 inspection every year, with a sweep once buildup reaches 1/8" of creosote — for a wood fireplace you actually use, that's about once a heating season. The neighborly part: since we're already on the roof, the same crew checks your dryer vent and caps the visit with a quick whole-home safety look, so one appointment covers what would otherwise be three.
Yes — our inspectors hold current CSIA (Chimney Safety Institute of America) certifications, verifiable in the CSIA member directory at csia.org, and we have NFI specialists for fireplace work. The same trained crew handles your chimney, fireplace, dryer-vent and air-duct needs, so you're not juggling four different contractors for one house.
Yes — 24/7 response (subject to crew availability) for active leaks, an animal trapped in the flue, post-fire damage, and storm damage, same-day in most cases. One call reaches one crew that can handle whatever the situation turns out to need, instead of bouncing you between specialists while the water's still coming in.
Always — a written quote before we lift a tool, with photos of what we found, so you see exactly what you're approving. If the same visit turns up something in the dryer vent or ducts, it goes on one itemized quote and one invoice rather than a string of separate trips.
The Whole-Home Care Plan is our annual maintenance plan at $19.99/month ($240/year): a Level 1 inspection and sweep ($248 value), priority scheduling, 10% off all repairs, and emergency-response priority. Because one crew covers chimney, fireplace, dryer-vent and ducts, the plan keeps the whole house on a single schedule instead of a calendar full of separate service calls. Cancel anytime, no contract.
Last reviewed:
Other services in the Pellet Stoves category.
Free written quote. Same-week scheduling. 24/7 emergency response when you need it.
Active leak, animal in flue, post-fire damage, or smoke event? Real humans on the line 7 AM to 12 AM every day — replies in under 2 minutes. Tech dispatch within 2 hours during business hours, subject to crew availability after-hours.
Emergency line